Sheep Carotid Model

The sheep carotid model is an in vivo experimental system that uses the sheep carotid artery to evaluate vascular biology, biomaterials, and cardiovascular devices under physiologically relevant conditions. Researchers surgically access the vessel and may implant a graft, stent, catheter, or other construct, allowing blood flow, vessel mechanics, and host tissue responses to be monitored over time. Its vessel size and anatomy support testing of engineered grafts, drug-delivery systems, and endovascular technologies before clinical translation. By connecting device design with patency, healing, thrombosis, and remodeling outcomes, this model helps bioengineers assess safety, performance, and limitations in a living system.

Sheep Carotid Model - Related Videos

Research

JoVE Journal - Medicine

A Novel Surgical Technique in a Sheep Model for Suburethral Graft Implantation

0 Views •

Cited by 1 •

2025

This article explains a new animal model designed for testing suburethral graft materials. In this model, a mesh tape is implanted through a vaginal incision in ewes, and the animals are observed over a three-month period. This model is essential as it lays the foundation for experimental research on grafts.

Research

JoVE Journal - Medicine

Establishment and Evaluation of a Sheep Model of Full-thickness Osteochondral Defect

0 Views •

2026

Here, we present an integrated protocol for generating controlled osteochondral lesions in sheep knees to establish an experimental model suitable for bone and cartilage tissue regeneration studies. The protocol outlines a method for inducing a full-thickness osteochondral defect in the femoral condyle, utilizing techniques that minimize animal welfare impacts and variability in results.

A Murine Model of Carotid Aneurysm Formation

0 Views •

2025

The present protocol describes a standardized surgical method for the induction of carotid aneurysms in a murine model through a single surgical operation.

Cannulation of the Carotid Artery in a Rat Model

0 Views •

2025

In this video, we demonstrate a surgical procedure to cannulate the left carotid artery in a rat model.

Research

JoVE Journal - Medicine
Free Sample

A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis

0 Views •

Cited by 11 •

2013

A model of stent implantation in mouse carotid artery is described. Compared to other similar methods, this procedure is very rapid, simple and accessible, offering the possibility to study in a convenient way the vascular wall reaction to different drug-eluting stents and the molecular mechanisms of restenosis.

View All Results

FAQs

Related Topics