Saturation Mode

Saturation mode is an operating region in semiconductor devices where a transistor’s output behavior changes because its controlling junctions or channel reach a limiting condition. In a bipolar junction transistor, the base-emitter and base-collector junctions are forward biased, producing a low collector-emitter voltage and making additional base drive yield little additional collector current; in a MOSFET, the channel pinches off near the drain as the drain voltage exceeds the gate-overdrive voltage. Engineers use these distinct saturation characteristics to design switching circuits, amplifiers, current sources, and digital logic. Understanding the relevant device physics helps predict voltage drops, power dissipation, gain, and switching performance.

Saturation Mode - Related Videos

Education

JoVE Core - Chemistry

Solution Equilibrium and Saturation

0 Views •

2020

Imagine adding a small amount of sugar to a glass of water, stirring until all the sugar has dissolved, and then adding a bit more. You can repeat this process until the sugar concentration of the solution reaches its natural limit, a limit determined primarily by the relative strengths of the solute-solute, solute-solvent, and solvent-solvent attractive forces. You can be certain that you have reached this limit because, no matter how long you stir the solution, undissolved sugar remains. The...

Research

JoVE Journal - Engineering

Patterning via Optical Saturable Transitions - Fabrication and Characterization

0 Views •

Cited by 1 •

2014

We report that the diffraction limit of conventional optical lithography can be overcome by exploiting the transitions of organic photochromic derivatives induced by their photoisomerization at low light intensities.1-3 This paper outlines our fabrication technique and two locking mechanisms, namely: dissolution of one photoisomer and electrochemical oxidation.

Special considerations while measuring oxygen saturation

0 Views •

2024

Assessing respiratory rate concurrently with pulse measurement is fundamental to patient care, providing valuable insights into the patient's respiratory function. The normal breathing rate for an adult usually falls within a normal range of 12 to 20 breaths per minute. Abnormal respiratory rates can signal underlying health conditions or the need for immediate intervention. Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.

A Protocol for Functional Assessment of Whole-Protein Saturation Mutagenesis Libraries Utilizing High-Throughput Sequencing

0 Views •

Cited by 5 •

2016

We present a protocol for the functional assessment of comprehensive single-site saturation mutagenesis libraries of proteins utilizing high-throughput sequencing. Importantly, this approach uses orthogonal primer pairs to multiplex library construction and sequencing. Representative results using TEM-1 β-lactamase selected at a clinically relevant dosage of ampicillin are provided.

Research

JoVE Journal - Chemistry
Free Sample

Spin Saturation Transfer Difference NMR (SSTD NMR): A New Tool to Obtain Kinetic Parameters of Chemical Exchange Processes

0 Views •

Cited by 4 •

2016

A detailed protocol describing the SSTD NMR method is presented here to help new users apply this new method to obtain the kinetic parameters of their own systems undergoing chemical exchange.