Ventricular Lead

A ventricular lead is an insulated wire that connects a pacemaker or implantable cardioverter-defibrillator to a heart ventricle, allowing the device to monitor and regulate cardiac rhythm. Its electrode senses intrinsic ventricular depolarization and, when needed, delivers precisely timed electrical impulses to stimulate myocardial contraction; in defibrillator systems, the lead can also support delivery of therapeutic shocks. Ventricular leads are placed through the venous system or attached during surgery, depending on the device and patient’s anatomy. They are essential in treating bradyarrhythmias, supporting coordinated pacing, and preventing complications associated with inadequate ventricular rate or conduction.

Ventricular Lead - Related Videos

Research

JoVE Journal - Bioengineering

In Vitro Thrombosis Test for Ventricular Assist Devices

0 Views •

2025

We present a benchtop protocol to induce thrombosis in ventricular assist devices (VAD) within a recirculating test platform. This method serves to identify thrombogenic hotspots in the blood flow path and can help improve thromboresistance ahead of preclinical testing in animal models.

Education

JoVE Science Education - Environmental Sciences

Lead Analysis of Soil Using Atomic Absorption Spectroscopy

0 Views •

2023

Source: Laboratories of Margaret Workman and Kimberly Frye - Depaul University Lead occurs naturally in soil, in levels ranging from 10-50 ppm. However, with the widespread use of lead in paint and gasoline in addition to contamination by industry, urban soils often have concentrations of lead significantly greater than background levels – up to 10,000 ppm in some places. Ongoing problems arise from the fact that lead does not biodegrade, and instead remains in the soil. Serious health risks...

Use of Two Intracorporeal Ventricular Assist Devices As a Total Artificial Heart

0 Views •

Cited by 4 •

2018

Here, we present a protocol using two centrifugal pumps as a total artificial heart replacement.

A Model of Long-Term Ventricular Fibrillation in Isolated Rat Hearts

0 Views •

2023

This protocol presents a model of long-term ventricular fibrillation in rat hearts induced by continuous stimulation with low-voltage alternating current. This model has a high success rate, is stable, reliable, and reproducible, has a low impact on cardiac function, and causes only mild myocardial injury.

Evaluation of Right Ventricular Function in Experimental Models of Pulmonary Arterial Hypertension

0 Views •

2025

The presentation of detailed methods for the evaluation of right ventricle function will enhance the quality and reliability of pulmonary hypertension research, offering a robust framework for future studies and enhancing reproducibility across different laboratories.

View All Results

FAQs

Related Topics